PRIMOVE STATIONARY

High power inductive charging for heavy duty operations

PRIMOVE transfers high power inductively across an air gap, without conductive contacts at the charging interface. We're developing the new 160 kW, 85 kHz platform and inviting OEMs to help shape its configuration and vehicle integration. Our proven 100 kW, 20 kHz system is available for horizontal and vertical installations.

White and blue vehicle ferry carrying several cars, departing from a concrete dock into calm water with forested islands in the background under a partly cloudy sky during sunset.
EXPLORE PRIMOVE

Discover the technology behind high power wireless charging

The 85 kHz system consists of an Inductive Power Supply (IPS), a Primary Wireless System (PWS) and a vehicle-mounted Pickup Rectifier (PicRec). The components transfer power from stationary infrastructure to a vehicle across an air gap. Explore the system architecture and its horizontal or vertical charging arrangement.

Since 2002
High power wireless charging in public transport
35M+ km
Heavy duty wireless vehicle operation
100 kW
Established 20 kHz systems available today
160 kW
Next generation 85 kHz platform in development
Image description
THE PRIMOVE ADVANTAGE

High power charging proven in daily operation

PRIMOVE builds on more than two decades of high power wireless charging in daily operation. From established 100 kW installations to the developing 160 kW platform, our systems combine contactless energy transfer, modular architecture and flexible integration for OEMs and infrastructure partners.

Proven high power wireless charging

ENRX IPT has supplied wireless charging technology for electric buses since 2002, with systems operating in public transport and maritime services. Our established 100 kW platform at 20 kHz draws on this experience and remains available today. The next generation 160 kW system at 85 kHz builds on a proven foundation.

Automatic charging without conductive contacts

PRIMOVE transfers energy inductively across an air gap, without conductive contacts at the charging interface. No connector needs to engage before energy transfer can begin, eliminating contact wear and a separate handling step. Charging can be integrated into normal stopping and parking positions, including installations exposed to water, salt and demanding operating conditions.

Modular charging architecture

PRIMOVE charging configurations can be dimensioned around the power demand and available charging positions. For the new 160 kW platform, we are developing shared power concepts where a central supply serves multiple inductive charging positions, with power distribution matched to the site's available grid capacity and simultaneous charging demand.

Integration designed around the vehicle and site

PRIMOVE supports horizontal and vertical charging arrangements, with stationary power electronics, inductive charging interfaces and receiving equipment integrated into the vehicle and infrastructure. We work with OEMs and system integrators to define mounting geometry, air gap, positioning tolerances, electrical interfaces and charging control for each project.

PRIMOVE 20 kHz horizontal and vertical charging interfaces
PRIMOVE 100 kW · 20 kHz

Proven 100 kW wireless charging available today

PRIMOVE's established 20 kHz system delivers 100 kW of contactless charging power. Horizontal, ground-integrated and vertical, facing-surface configurations allow the charging interface to be integrated into different vehicle and infrastructure layouts. ENRX IPT supplies the system components and supports OEM integration, service and existing installations.

PRIMOVE 100 kW technical details

Specifications of the proven 20 kHz system, shown separately for horizontal and vertical charging configurations.

Horizontal installation · 20 kHz

COMPONENT
RATED POWER
KEY SPECIFICATION
PROTECTION
Charge Module · 4140010
100 kW
2990 × 1440 × 811 mm · >93% efficiency
IP67
F-Pickup · 4150247
2 × 50 kW
1100 × 1076 mm · incl. connector
IP67
Rectifier · 4160110
2 × 50 kW
600 × 310 × 110 mm · Liquid cooled
IP65
In-Ground Module · 4140006 / 4140002
—
3100 × 1550 × 1030 mm · Left/right variants
—
Track Supply · 4180005-DIGI2
100 kW
1993 × 791 × 507 mm · 400 V
IP67
Monitoring Unit · 4140011 / 4180140
100 kW
1010 × 410 × 1900 mm · Indoor
IP54
Scroll to see the full table

Vertical installation · 20 kHz

COMPONENT
RATED POWER
KEY SPECIFICATION
PROTECTION
Charge Pad · 4180008
2 × 50 kW
1000 × 1100 × 90 mm · Flexible mounting
IP67
F-Pickup · 4150247
2 × 50 kW
600 V · 83 A per unit
IP67
Track Supply · 4180005-DIGI2
100 kW
1993 × 791 × 507 mm · 400 V
IP67
Rectifier · 4160110
2 × 50 kW
600 × 310 × 110 mm · Liquid cooled
IP65
Monitoring Unit · 4140011 / 4180140
100 kW
400 V · indoor/outdoor
IP54
Scroll to see the full table
Downloads

Insights and resources

Download brochures and expert materials on our technologies and their industrial applications.

Datasheet Horizontal 100 k\W 20 kHz

Download now

Datasheet Vertical 100 kW 20 kHz

Download now

RELATED APPLICATIONS

Explore PRIMOVE charging applications

Explore how different systems can be powered and charged, with technical information for each application.

PROVEN IN OPERATION

High power wireless charging in service since 2002

Case study image
Fredrikstad, Norway

145 automatic wireless ferry charges every day

145

charges per day

112 sec

average charge

5

electric ferries

View case study
Case study image
Turin, Italy

22 years of wireless bus charging without component replacement

22 yrs

original components

95%

system availability

23

electric buses

View case study
Case study image
Braunschweig, Germany

12 years of wireless charging in Braunschweig

12+ yrs

in service

4.5M km

fleet distance

5

electric buses

View case study
Case study image
Madrid, Spain

Converting Madrid’s bus fleet with wireless charging

8 min

charging time

5

buses converted

90%

charging efficiency

View case study
Case study image
Berlin, Germany

Wireless charging on Berlin’s bus line 204

200 kW

wireless charging

4–7 min

charging time

4

electric buses

View case study
Case study image
Södertälje, Sweden

Scania’s seven-minute wireless charge

7 min

wireless charge

10 km

per charge

190 km

daily operation

View case study
Case study image
Milton Keynes, United Kingdom

Eight electric buses, two wireless charging points

17 hrs

daily operation

250 km

per bus daily

2

charging points

View case study
Case study image
Bruges, Belgium

Wireless bus charging in historic Bruges

12 min

wireless charge

36 kWh

onboard battery

45 min

driving per charge

View case study
Case study image
London, United Kingdom

London double-deckers prove wireless charging in daily service

60%+

operation in electric mode

100 kW

wireless charging power

43,664 km

electric-mode travel, Apr-Dec 2016

View case study

Discuss your charging requirements with our engineers

Get involved in developing the new 160 kW platform or request a proven 100 kW charging system. We'll help review your vehicle, infrastructure and power requirements.

Discuss your application
View of Earth from space showing the Indian subcontinent, surrounding countries, the Arabian Sea, and the Bay of Bengal with cloud formations and a dark space background.
Portrait of Christian Köbel.

Christian Köbel

Director of Sales & Business Development
christian.koebel@enrx.com+41 79 770 54 26
Portrait of Dr Sergio Perez.

Dr Sergio Perez

Business Developer Manager e-Mobility
sergio.perez@enrx.com+49 151 467 20 611

What OEMs want to know about PRIMOVE Stationary

Answers on system design, power levels, installation and integration.

Discuss your application

What is the difference between 85 kHz and 20 kHz PRIMOVE?

The new 85 kHz PRIMOVE platform provides a different architecture for 160 kW wireless charging. Our established 20 kHz technology offers 100 kW configurations. The generations have distinct system designs and their components should not be regarded as interchangeable.

How can OEMs get involved in the 160 kW development?

We're inviting OEMs and system integrators to engage while the 85 kHz platform is still being developed. We want to understand vehicle mounting space, receiving unit orientation, electrical interfaces, charging configurations and operating requirements early enough for these needs to help shape the final system design. Contact our engineering team to discuss your application.

Can PRIMOVE be installed horizontally or vertically?

Yes. PRIMOVE technology supports different mounting arrangements. Horizontal systems place the charging interface beneath the vehicle, while vertical systems transfer energy between facing surfaces. The exact configuration depends on the selected generation and installation.

Does PRIMOVE require precise positioning?

Charging coils must be aligned within the specified tolerances of the selected system. The permitted air gap and positioning range depend on the charging interface and installation geometry.

Can multiple charging interfaces be combined?

Modular configurations and shared power infrastructure are part of the next generation development. Total charging power, simultaneous use and system layout are determined for each project.

Is the 100 kW 20 kHz system still supported?

Yes. ENRX IPT supports established 20 kHz installations and can assess suitable configurations for new projects, upgrades and service. Availability and compatibility depend on the project and component selection.